Jaguar Braided Long Sheath

JAGUAR CATHEHER is designed to perform as a guiding catheter and an introducer sheath.  JAGUAR CATHEHER is designed to be used for the introduction of interventional and diagnostic devices into the human vasculature, including but not limited to the lower extremities, renal arteries, and carotid arteries.

  • OVERVIEW
  • FEATURES
  • SPECS
  • ORDERING INFO

JAGUAR CATHEHER is designed to perform as a guiding catheter and a long introducer Sheath. The catheter is coil reinforced, has a radiopaque marker and hydrophilically coated. It comes packaged with a dilator and choice of hemostatic valve types.

Highly flexable and  reinforced introducer sheath is designed to resist kinking. It incorporates a radiopaque marker located approximately 5mm proximal to the tip. Jaguar is available in several distal segment shapes. The sheath has an atraumatic tip which is hydrophilically coated.

The exact proper of the dilator in the sheath allows for simultaneous motion of both dilator and sheath. The shape of the dilator compliments the shape of the sheath. The radiopacity of the dilator has been greatly enhanced to increase the visibility. The diatal segment of the dilator has been minimized to extend approximately 2 cm beyond the tip of the sheath.

Every Jaguar Catheter  has y shaped valve types are equipped with three way stopcock connected by a side tube.

Designed to work with

Maintains shape and positioning: Outstanding durability, even in the longest procedures

Resists kinking: Stainless steel coil for consistent reliability

Allows easy penetration and smooth transition.

Atraumatic tip: Minimizes potential for vessel damage

Smooth transitions: Guidewire-to-dilator-to sheath

Provides lesion access: Exceptional trackability, even in the most challenging anatomy

Enhances visualization for precise positioning: Triple radiopacity (sheath, dilator and coil marker)

Provides smooth movement: Coil reinforced tubing and PTFE inner layer that minimizes friction

Shapes and sizes to meet your peripheral challenges

Specification  

  • Maximum Guidewire Size 0.038" / 0.97 mm
  • Radiopaque Marker Coil design and radiopaque marker at 5 mm from the distal tip of the sheath
  • Reinforcement inside the sheath Stainless steel coil
  • Sheath Inner Layer PTFE polyetrafluoroethylene
  • Maximum Guidewire Size 0.038"/0.97 mm
  • Structure of the Catheter PE/PEBAX
Order NumberDevice inner diameterWorking LengthShape
NR11616.0 Fr45 cmStraight
NR11626.0 Fr45 cmAngled
NR11636.0 Fr45 cmTapered
NR11647.0 Fr45 cmStraight
NR11657.0 Fr45 cmAngled
NR11667.0 Fr45 cmTapered
NR11676.0 Fr65 cmStraight
NR11686.0 Fr65 cmAngled
NR11696.0 Fr65 cmTapered
NR11707.0 Fr65 cmStraight
NR11717.0 Fr65 cmAngled
NR11727.0 Fr65 cmTapered
NR11736.0 Fr90 cmStraight
NR11746.0 Fr90 cmAngled
NR11756.0 Fr90 cmTapered
NR11767.0 Fr90 cmStraight
NR11777.0 Fr90 cmAngled
NR11787.0 Fr90 cmTapered