Mantis Curve OTW Thrombectomy System

This over-the-wire rheolytic thrombectomy device uses the Venturi effect to create a hydrodynamic vortex that draws in and fragments the surrounding thrombus. The system requires use of a specialized system that creates Rotational vortex effect prevents embolism and macarates thrombus with TPA while preventing distal embolism.


 

  • OVERVIEW
  • FEATURES
  • SPECS
  • ORDERING INFO

Sinusoidal wawe shaped tip design Contacts whole vessel lumen and effects wall adherent thrombus Allows movement over 0.035” guidewire Creates vortex effect and macarates thrombus with TPA while preventing distal embolism Active type Preserves vessel wall Excellent steerability Built-in infusion port allows infusion of TPA and contrast media Type diameter size ranging from 150 mm Allows physician to perform treatment depending on application area and vessel size Decreases thrombolytic treatment dose significantly Prevents post-thrombolytic syndrome significantly Decreases length of stay in hospital Quick Setup.

Atraumatic rotational distal tip allows reliable operation Allows movement over 0.035” guidewire Mantis Curve transfers torque in the ratio of 1:1(distal/proximal) by the help of its flexible helical internal structure. Treat severely thrombus up to 2 times more effectively. 15000 RPM The device is available in multiple sizes, including 5, 6, 7 and 8 Fr.

Atraumatic rotational distal tip allows reliable operation.

Allows movement over 0.035” guidewire.

Mantis Curve transfers torque in the ratio of 1:1(distal/proximal) by the help of its flexible helical internal structure.

Treat severely thrombus up to 2 times more effectively.

15000 RPM

Indicated Vessels

  • Peripheral Veins
  • Pulmonary Artery
  • Inferior Vena Cava
  • Subclavien Vein
  • Hepatic Vein

ADVANTAGES

  • Sınusoidal wawe shaped tip design
  • Contacts whole vessel lumen and effects wall adherent thrombus
  • Allows movement over 0.035” guidewire
  • Creates vortex effect and macarates thrombus with TPA while preventing distal embolism
  • Active tip
  • Preserves vessel wall
  • Excellent steerability
  • Built-in infusion port allows infusion of TPA and contrast media
  • Tip diameter size ranging from 150 mm
  • Allows physician to perform treatment depending on application area and vessel size
  • Decreases thrombolytic treatment dose significantly
  • Prevents post-thrombolytic syndrome significantly
  • Decreases length of stay in hospital
  • Quick Setup

Specification

   

  • Design Coil design and Sinusoidal wawe shape
  • Guidewire Compatibility 0,035"
  • Catheter Lenght 90 cm, 110cm
  • Catheter Profile 120cm, 135cm
  • Radiopacity 5.0F - 6.0F - 7.0F - 8.0F
  • Active Zone Coil design and Sinusoidal wawe shape is visible from the distal tip to proximal
  • Catheter Inner Layer 15 cm
  • Structure of the Catheter PTFE


 

Order NumberDevice outer diameterWorking LengthTip DesignActive Zone
VS10447.0 Fr90 cmSinisoidal Wave15 cm
VS10458.0 Fr90 cmSinisoidal Wave15 cm
VS10467.0 Fr110 cmSinisoidal Wave15 cm
VS10478.0 Fr110 cmSinisoidal Wave15 cm
VS10487.0 Fr135 cmSinisoidal Wave15 cm